compare_arrows
Respiratory protection kit for 1 person with a full-face mask, ambient air pump & 50 feet, Allegro, 9200-01.
search
  • Respiratory protection kit for 1 person with a full-face mask, ambient air pump & 50 feet, Allegro, 9200-01.
Allegro

Respiratory protection kit for 1 person with a full-face mask, ambient air pump & 50 feet, Allegro, 9200-01.

RA9200
$2,488.35
Quantity

Return conditions:

No returnable if used. For more information about our return policy, please refer to the Orders and Returns.

Respiratory protection kit for 1 person with a full-face mask, ambient air pump & 50 feet, Allegro.

Allegro respiratory protection kit for one worker included: one low-pressure air source powered air-supply pump, one 50-foot-long hose and one full-face mask respirator, one size fit most (medium/large).

Code of the manufacturer Allegro: 9200-01.

This kit offers an all-set configuration to provide respiratory protection for one person. The pump is designed to transfer breathable air from an uncontaminated location to a worker who requires supply air. The ambient air pump connects to a standard power outlet, eliminating the need for special wiring and electrical compatibility issues. In addition, it can be easily transported from one job site to another.

This set contains:

For more specific information about the products included in this set, consult the product sheet by clicking on the product code in green.

Application:
This type of respiratory protection is recommended for work that will release solid and liquid particles into the air or work in environments where you find contaminants and/or biological particles in the air. The air supply system is required when the worker is in the presence of a contaminant that cannot be filtered by cartridges or filters.

Restriction:
You should not use a respirator when a beard is visible. Indeed, facial hair or any other condition that may prevent direct contact between the edge of the mask and the face may compromise a worker’s safety by not fully protecting him.

This kit offers a protection factor of 1000 NIOSH approved when you fully use all components designated by the manufacturer Allegro. You must check the level of respiratory risk associated with its use. The manufacturer has designed its products for environments with contaminant concentrations that do not exceed the limit that results in the immediate death of the worker (IDLH). This must be taken into account if the pump stops working. In addition, be sure to choose the location of your air source wisely because the pump is designed to transfer breathing air from an uncontaminated area to a worker. This kit offers a protection factor up to 1,000 times the exposure limit allowed by the CNESST or any other applicable government regulation. This kit is not recommended for sandblasting work. Do not use this respirator kit in areas where there is a risk of oxygen deficiency.

Maintenance and service life:

Mask maintenance:
This kit is reusable as long you provided the maintenance and storage according to the rules. Allegro recommends that you always inspect your mask before using it, clean it after using it, and keep it in its packaging when it is not in use. When cleaning, you should not use solvents since they can weaken some components of the mask, which can affect its effectiveness.

Pump maintenance:
The ambient air pump must not be fed to a generator. To avoid damaging the pump, we recommend that you attach the hose and the face part before starting it. Replace the inlet (RA9700-07) and exhaust (RA9700-02) filters after 200 hours of use. Replace carbon vanes around 400 to 500 hours of use (RA9700-41S).

Hose maintenance:
This hose could be washed by hand with cold or warm water and a mild detergent, thoroughly rinsed the inner part of the hose to remove traces of soap. It must also be dried in the open air away from the sun’s rays.

Suggestions:
Also take care to provide you with spare parts for the full-face respirator such as: the exhalation valve (RA9901-07), the inhalation valve (RA99901-03B) and peel-off to protect your visor (RA9901-25). And why not the parts of engine maintenance: the inlet filter (RA9700-07) and exhaust filter (RA9700-02), carbon vanes (RA9700-41S). Please note that his items are available only on special order only, the supply may vary from 2 to 3 weeks.

Possible other configurations:
The RA9806 (A-300) pump offers the ability to be configured with different size hoses as well as with other facial parts. You can choose air supply hoses of 25, 50 or 100 feet (RA9100 and RA9100-100), choose up to 1 type respirator half mask (RA9920) or full-face mask (RA9901). By cons you cannot use a hood.

To Consider Before Buying:
If you chose this specific model of respiratory protection, it is to protect a worker with a full-face respirator. You must remember that if you intend this kit to a man it must be finely shaved before using it. From experience we know that this requirement prescribed by standards (CSA and NIOSH) and by government agencies is very difficult to obtain daily. Your challenge will be to require the male worker to be finely shaved and to monitor daily or to opt for a hood. The problem with this model pump is that it cannot provide breathable air to a worker equipped with a hood. The capacity of the pump does not allow it. To obtain a powerful enough pump to feed a worker equipped with a hood you must choose the pump (RA9821) or the kit with hood (RA9220).

For more technical details, please refer to the attached PDF documents on” Download “tab under ‘More info’ tab.

RA9200

Data sheet

Type of product
Safety equipment
Main category
Personal protection
Sub category
Respiratory protection
Sub sub category
Allegro low pressure air-supplied respirators
Name of the product
Respiratory protection kit
Product code
RA9200
Approved/Certified
Meets NIOSH
Manufacturer
Allegro industries
Country of origin
United State of America
Protection factor
Protection factor of 1000
Air supply system
Low pressure
Facial part
Include 1 kit of full-face mask & breathing hose and belt, model RA9901
Facial part Material
Silicone
Facial part Protection
Anti-fog and anti-scratch coatings and Distortion free
Visor coating
Anti-fog and scratch resistant
Removable protector
Include one self-adhesive peel-off for full face respirator ref: RA9901-25
Type of harness
5 attachement points + net
Respirator / mask sizes
One size fits all
Respirator / mask characteristics
Equipped with a contoured, large diameter exhalation valve that reduces breathing resistance for the worker
Type of connection
OBAC quick-connect plug with wide diameter and minimal air restriction
Pump Type
Carbon rotary vane and oil-less motor
Pump Vanes
Carbon construction
Pump Inlet filter
40.0 Micron made of bronze and steel
Pump Exhaust filter
0.30 Micron HEPA
Pump Pressure gage
1½" / 3.8cm) face, steel housing (0-15 psi) / (0-1.03 bar)
Pump Working press
2-12 psi / 0.14-0.83 bar - 15 psi / 1.03 bar max
Pump Performance
0-5 CFM / 0-8.5 m³/hr - for a 1/4 HP motor
Motor (HP)
1/4 HP
Motor in Volts
115 V / 230 V AC, single phase
Motor Current draw
5.5 A for the 1/4 HP pump
Hose material
Polyvinyl chloride with reinforced braided polyester yarn
Hose temperature range
-20°F to 150°F / -28.8°C to 65.5°C
Hose length
50 Feet / 15.24 m
Hose Max pressure
185 psi à 70° F / 12.76 bar à 21.1°C
Material
See items separately
Washable
Washable mask
Length (in/cm)
22 in / 55.88 cm
Width (in/cm)
17 in / 43.18 cm
Height (in/cm)
15 in / 38.1 cm
Weight (lb/kg)
43 lb / 19.5 Kg
Sold by
Unit
Return conditions
No returnable if used. For more information about our return policy, please refer to the "Orders and Returns" link on the home page
New

Download

RA9901 Full face explosive view

RA9901 Allegro low pressure full face mask explosive view.

Download (675.44KB)

RA9901 Full face technical sheet

RA9901 Allegro low pressure full face mask technical sheet.

Download (103.07KB)

RA9806 1/4 HP explosive view

RA9806 Allegro low pressure pump 1/4 HP A-300 explosive view.

Download (670.32KB)

RA9806 1/4 HP technical sheet

RA9806 Allegro low pressure 1/4 HP A-300 technical sheet.

Download (83KB)

RA9100 Technical sheet hoses

RA9100 Allegro low pressure hoses technical sheet.

Download (43.66KB)

You might also like